Repairs and Adjustments
REP 30 Thermostat
Parts List on:
PL 12
Switch off the electricity to the machine. Disconnect the power cord from the customer supply
while performing tasks that do not need electricity. Electricity can cause death or injury. Moving
parts can cause injury.
Do not touch the fuser while it is hot.
Preparation:
•
Remove the paper exit assembly,
•
Remove the fusing lamp and hot roller,
Removal
1. Remove the thermostat, Figure 1 and Figure 2.
4-74
WARNING
WARNING
REP
26.
REP
27.
Location of the thermostat on the fuser
Figure 1
04/08