REP 37 Discharge Lamp Assembly

Parts List on:
PL 11
Switch off the electricity to the machine. Disconnect the power cord from the customer supply
while performing tasks that do not need electricity. Electricity can cause death or injury. Moving
parts can cause injury.
Preparation
Remove the fusing unit,
Removal
1. Remove the discharge lamp assembly, Figure 1.
2
Disconnect the discharge
lamp harness
Phaser 3100 MFP
WARNING
REP
25.
1
Remove 1 screw to release the
ground harness
Figure 1
04/08
Repairs and Adjustments
3
Remove 1 screw at each end
to release the discharge lamp
assembly