3.27 [1-1] Slot—Card Property - EM type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Maintenance Console Location
3.27 [1-1] Slot—Card Property - EM type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
Pulse Dial—Pulse Feed Back Tone
Specifies whether the pulse feedback tone is turned on or not. For outgoing trunk calls, audible tones can be
heard as the dialled number is sent out, which informs the extension user that the number has been dialled.
Value Range
No, Yes
Maintenance Console Location
3.27 [1-1] Slot—Card Property - EM type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
Pulse Dial—Pulse Maximum BREAK Width
Specifies the maximum length of the break signal in a pulse dial.
Value Range
8 ´ n (n=9–20) ms
Maintenance Console Location
3.27 [1-1] Slot—Card Property - EM type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None