Panasonic KX-TDA100 Programming Manual page 153

Hybrid ip-pbx, pc programming manual
Hide thumbs Also See for KX-TDA100:
Table of Contents

Advertisement

Maintenance Console Location
3.13 [1-1] Slot—Card Property - BRI type/PRI type
Programming Manual References
None
Feature Guide References
None
ISDN CO / QSIG Master / QSIG Slave—T301
Specifies the maximum time that the PBX waits for a reply after making a call to ISDN.
Value Range
0–18000 ´ 100 ms
Maintenance Console Location
3.13 [1-1] Slot—Card Property - BRI type/PRI type
Programming Manual References
None
Feature Guide References
None
ISDN CO / QSIG Master / QSIG Slave—T302
Specifies the maximum time allowed between each digit on an incoming call. Applies to overlap receiving.
Value Range
0–600 ´ 100 ms
Maintenance Console Location
3.13 [1-1] Slot—Card Property - BRI type/PRI type
Programming Manual References
None
Feature Guide References
None
3.13 [1-1] Slot—Card Property - BRI type/PRI type
PC Programming Manual
153

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tda30Kx-tda200Kx-tda600

Table of Contents