3.19 [1-1] Slot—Port Property - T1 Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Private: Use the TIE line service between two or more PBXs.
Maintenance Console Location
3.19 [1-1] Slot—Port Property - T1 Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
1.1.1.1 Incoming Trunk Call Features—SUMMARY
1.21.1.1 Integrated Services Digital Network (ISDN)—SUMMARY
1.30.1 TIE Line Service
CPC Signal Detection (DDI/DID)—Outgoing, Incoming
Specifies the length of time required by the PBX to detect a CPC signal on outgoing or incoming trunk calls
before disconnecting the line. When None is selected here, the line will not be disconnected when a CPC
signal is not detected.
This setting is only available when Channel Type on this screen is set to DDI/DID.
Value Range
None, 80 ´ n (n=2–75) ms
Maintenance Console Location
3.19 [1-1] Slot—Port Property - T1 Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
1.11.10 Calling Party Control (CPC) Signal Detection
CPC Signal Detection (LCO/GCO)—Outgoing, Incoming
Specifies the length of time required by the PBX to detect a CPC signal on outgoing or incoming trunk calls
before disconnecting the line. When None is selected here, the line will not be disconnected when a CPC
signal is not detected.
This setting is only available when Channel Type on this screen is set to GCOT or LCOT.
Value Range
None, 8 ´ n (n=2–112) ms
Maintenance Console Location
3.19 [1-1] Slot—Port Property - T1 Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
230