Panasonic KX-TDA100 Programming Manual page 223

Hybrid ip-pbx, pc programming manual
Hide thumbs Also See for KX-TDA100:
Table of Contents

Advertisement

Feature Guide References
None
Flash—Flash Signal Detection (OPX)
Enables the PBX to detect hookswitch flash signals from an SLT connected to an OPX.
Value Range
Disable, Enable
Maintenance Console Location
3.18 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
Flash—Minimum BREAK Width (OPX)
Specifies the minimum length of the break signal in a flash signal from an SLT connected to an OPX.
Value Range
8 ´ n (n=3–63) ms
Maintenance Console Location
3.18 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
Flash—Flash Width (OPX)
Specifies the maximum length of a flash signal sent from an SLT connected to an OPX that the PBX can
recognise as a hookswitch flash signal.
Value Range
8 ´ n (n=3–191) ms
3.18 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)