Connecting The Network Cable; Figure 2-7 Main Alarm Adapter Input (Detail); Table 2-6 Alarm Input Pin Definitions - Honeywell HDZ20HD User Manual

Hdz series ip ptz dome
Hide thumbs Also See for HDZ20HD:
Table of Contents

Advertisement

1 2 3 4 5 6 7 8 9 10 11 12

Connecting the Network Cable

Connect a Category 5 or higher Ethernet cable to the RJ45 connector on the back plate of the
camera (see
(100 m). After you have connected the Ethernet cable, check the status of the LED indicators on
the RJ45 connector. If the LEDs are not lit, re-check the connection.
Figure 2-7
Main Alarm Adapter Input (Detail)
Table 2-6
Alarm Input Pin Definitions
Pin
Definition
1
Alarm Out NO 1
2
Alarm Out NC 1
3
Alarm Out COM 1
4
GND
5
Alarm Out NO 2
6
Alarm Out NC 2
Figure 2-5
on
page
The green LED indicates a network connection.
The orange LED indicates network activity.
Note
You may need to use a crossover cable if you are connecting the
camera directly to a PC.
Inputs (x4)
5V, 4700 Ohms, pull up
Outputs (x2)
Relay output, 120 V AC/30 V DC, 3 A MAX
Note
Use alarm outputs for SELV circuits only.
Pin
7
8
9
10
11
12
29). The Ethernet cable should not be longer than 328 feet
Installing the Camera | 31
Definition
Alarm Out COM 2
GND
Alarm In 4
Alarm In 3
Alarm In 2
Alarm In 1
800-11873V4 - A - 07/2014

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents