2.4 HD6 RUGGED DOME HOUSING

WARNING: Installation must be performed by qualified technical
personnel and must be in accordance with all national and local
mechanical and electrical codes.
Perform the following steps to install a rugged dome housing.
1. Select the location(s) of the housing (s). Each HD6 requires a 24Vac ± 10% power
source measured at the dome. Ensure a 24Vac @ 1.1A power source is available.
The blower only option requires an additional 24Vac @ 0.5A power source.
2. Secure a safety cable (supplied by installer) to a building support structure.
Honeywell Video Systems recommends using 3/32" plastic coated aircraft cable
(part 849518-0311) and splicing sleeves (part 849511-0057). These parts can be
ordered from the Honeywell Video Systems parts sales department.

Figure 4: Safety Cable Installation

3. Attach the safety cable from the building structure to the mounting bracket. Route
the safety cable through one side of a splicing sleeve (not supplied), then through
the hole in the side of the mounting bracket, then through the other side of the
splicing sleeve. Secure the safety cable by crimping the splicing sleeve.
Rev. 1.02
SAFETY CABLE INSTALLATION
ATTACH THE SAFETY CABLE
TO A BUILDING SUPPORT STRUCTURE
SPLICING SLEEVE
SAFETY CABLE
SPLICING SLEEVE
LOOP THROUGH HOLE
IN MOUNTING BRACKET
(SAFETY CABLE SUPPLIED BY INSTALLER)