Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

ELECTRIC HEATER ELEMENT

Heater Terminal Block
Refer to page 4-8 for the procedure for access-
ing the heater.
1. Unplug dryer or disconnect power.
2. Disconnect one of the wire connectors from
the heater terminal block.
3. Set the ohmmeter to the R X 1 scale.
4. Touch the ohmmeter test leads to the termi-
nals on the heater terminal block. The meter
should indicate between 7 and 12 Ω.
WARNING
Electrical Shock Hazard

BLOWER CAPACITOR

Refer to page 4-14 for the procedure for ac-
cessing the blower capacitor.
1. Unplug dryer or disconnect power.
2. Turn off gas supply to dryer.
IMPORTANT: Discharge the capacitor by
touching a 20,000 Ω resistor to the terminals
and chassis ground.
3. Disconnect the wires from the capacitor
terminals.
4. Set the ohmmeter to the R X 10K scale.
5. Touch the ohmmeter test leads to the two
capacitor terminals. The meter should in-
dicate a low resistance, and then gradually
increase towards infinity.