Kitche JLid
° PROLINE Dryer
TiPS FOR BEST PERFORMANCE OF ELECTRIC DRYER
See installationinstructions for more detailed information,
Not for direct wire installations.
Clean,
correct
venting
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death or fire.
Existing vent should be cleaned before connecting
dryer and then every two years for best performance.
Replace plastic vent with rigid
metal or flexible metal vent.
Vent should be 4" (10.2 cm) wide.
Use one of the following Vent system charts to determine type of vent material and
hood combination
acceptable to use.
NOTE: Flexible metal vents are acceptable only if accessible for cleaning and the
total length does not exceed 8 ft (2.4 m).
Vent system chart = rigid metal vent only
Numberof 90° turns or elbows ,_Typeof vent
Rigid metal
0
Rigid metal
Box or Iouvered hoods
174 ft (53.0 m)
164 ft (50.0 m)
2
Rigid metal
184 ft (46.9 m)
._,
(E_
3
metal
145 ft (44.2 m)
Angled hoods
168 ft (81.2 m)
158 ft (48.0 m)
148 ft (48.1 m)
139 ft (42.4 m)
131 ft (39.9 m)
Plug into the outlet.
Clean the lint screen
before every load.
A level
dryer
Proper
electrical
supply
for dryer
3957656
Cd,p 2006. All rights reserved.
Use clamps to seal all joints. Do
Make the vent as short as
not use duct tape or screws,
possible with the fewest number
of turns.
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief,
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal
(silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals
(gold).
Securely tighten
all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
If using existing vent remove lint
Remove lint from hood. Flapper or
from the entire length of vent.
louvers should move freely.
Vent system chart - rigid metal vent used with a maximum of 8 ft (2.4 m)
flexible
metal vent
Number of 90° turns or elbows
o
Type of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box or Iouvered hoods
Ang ed hoods
134ft (40.8 m)
128ft (39.0 m)
125ft (38.1 m)
119ft (36.3 m)
117ft (35.7 m)
111ft (33.8 m)
All four dryer feet were preset to the same height at the factory.
After the dryer is level, use a
Use a gA_"(14 ram) wrench to
Slide the dryer to its final location
verify that the nuts on the two rear
and check the levelness side to
_A_"(14 ram) open-end wrench to
preset feet are tightened against
side and front to back.
turn the nuts on the feet tightly
the cabinet,
against the dryer cabinet.
NOTE: If the dryer is not level, refer to the Use and Care Guide for more information.
Disconnect power before making electrical connections.
Electric dryer requires a
240 volt electrical supply. Without the correct electrical supply, your dryer may
tumble clothes, but will not heat to dry the clothes. For more information, see
Installation Instructions.
Check your outlet to determine
...or 4-wire 30-amp power supply
Use a UL listed strain relief and
whether you should use a new UL
cord.
make sure it is tightened.
listed 3 wire...
Electric dryers use 2 household fuses or circuit breakers. The drum may be
turning, but you may not have heat if one of the fuses has opened, or if one of
the circuit breakers has tripped.
M