WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug dryer or disconnect power.
2.
Turn off gas supply to dryer.
3.
Remove the belt and drum from the dryer
(see pages 4-19 through 4-21 for the pro-
cedure).
3 Wire Retainers
& AC Wiring
REMOVING A SIDE PANEL
Terminal
4-26
4.
Remove the left and right console screws
and capture nuts.
5.
Open the three wire retainers (see the photo
to the left) and remove the AC wiring.
6.
Disconnect the drive motor connector from
the main harness plug.
7.
Remove the blower motor assembly from the
dryer (see page 4-16 for the procedure).
Drive Motor Connector
Blower Motor Assembly
8.
Electric Models: Disconnect the following
connectors from the heater assembly:
a) Terminal Block (RD & BK wires)
b) Thermal Cutoff (TCO) (RD wire)
c) High Limit Thermostat (RD wire)
Red
Block
Black
Red
High Limit
Thermostat
Screw & Capture Nut
Front Panel
Electric Heater
Assembly
Red
TCO