Accessing & Removing The Blower Assembly - KitchenAid Pro Line KHEV01RSS Technical Education

Front-loading gas and electric dryers
Hide thumbs Also See for Pro Line KHEV01RSS:
Table of Contents

Advertisement

6.
Remove all the wire connections to the
machine control board. See Figure 11
below.
7.
Remove screws that fasten the control
board to the mounting bracket, and pull it
from the mounting bracket.
ACCESSING & REMOVING THE
BLOWER ASSEMBLY
The blower assembly includes the tempera-
ture sensor, exhaust high limit, lint drawer
switch, and blower motor. See Figure 12.
Figure 12.
Blower motor components
NOTE: J connectors shown on the machine control electronics correspond with P connectors on the wiring diagram.
Figure 11. Machine Control Electronics
ACCESSING THE BLOWER
ASSEMBLY COMPONENTS
1.
Unplug dryer or disconnect power.
2.
Turn off gas supply to dryer.
3.
Remove the back panel and the duct
support bracket from the dryer.
4.
Remove the toe panel from the dryer front.
5.
Remove the 2 blower motor housing
screws from the dryer front.
6.
To remove the temperature sensor:
a) Pull the blower motor housing assem-
bly far enough forward so you can ac-
cess the temperature sensor.
b) Disconnect the two red-silver wires
from the exhaust high limit manual re-
set terminals. See Figure 13.
Exhaust High
Limit Wires
Temperature
Sensor Connector
Figure 13. Temperature sensor connections
6-29
Blower Motor Top Temperature
Housing Cover
Sensor Clip
Temperature Sensor
Harness Connector