ACCESSING THE BLOWER
ASSEMBLY COMPONENTS
1.
Unplug dryer or disconnect power.
2.
Remove the back panel and the duct
support bracket from the dryer.
3.
Remove the toe panel from the dryer
front.
4.
Remove the 2 blower motor housing
screws from the dryer front.
5.
To remove the temperature sensor:
a) Pull the blower motor housing assem-
bly far enough forward so you can ac-
cess the temperature sensor.
b) Disconnect the two red-silver wires
from the exhaust high limit manual re-
set terminals. See Figure 12.
c) Unlatch and disconnect the 4-pin har-
ness connector from the temperature
sensor connector.
d) Disconnect the 4-pin sensor connec-
tor from the mounting bracket.
e) Remove the front clip from the tem-
perature sensor. To do this, hold the
clip with a pair of pliers, and twist the
sensor with your fingers while pushing
it out of the clip.
6.
To remove the lint drawer switch:
a) Unlatch and disconnect the 4-pin har-
ness connector from the temperature
sensor connector. See Figure 12.
Exhaust High
Temperature
Blower Motor Top
Limit Wires
Sensor Clip
Housing Cover
Temperature
Sensor Connector
Temperature
Harness Connector
Sensor
Figure 12.
Temperature sensor connections.
6-14