KitchenAid Pro Line KHEV01RSS Technical Education page 20

Front-loading gas and electric dryers
Hide thumbs Also See for Pro Line KHEV01RSS:
Table of Contents

Advertisement

3-wire connection: Direct wire
Use where local codes permit connecting
cabinet-ground conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of ex-
tra length so dryer can be moved if needed.
Strip 3-1/2˝ (8.9 cm) of outer covering from
end of cable. Strip insulation back 1˝ (2.5 cm).
If using 3-wire cable with ground wire, cut bare
wire even with outer covering. Shape ends of
wires into a hook shape.
When connecting to the terminal block, place
the hooked end of the wire under the screw of
the terminal block (hook facing right), squeeze
hooked end together and tighten screw, as
shown.
1. Loosen or remove center silver-colored
terminal block screw.
2. Place the hooked end of the neutral wire
(white or center wire) of direct wire cable
under the center screw of terminal block
(hook facing right). Squeeze hooked end
together. Tighten screw.
B
A
A. External ground conductor screw
B. Neutral ground wire
C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
³⁄
E.
" (1.9 cm) UL listed strain relief
4
3. Place the hooked ends of the other direct
wire cable wires under the outer terminal
block screws (hooks facing right). Squeeze
hooked ends together. Tighten screws.
4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot
of dryer rear panel. Secure cover with
hold-down screw.
6. You have completed your electrical connec-
tion. Now go to "Venting Requirements,"
page 2-15.
Optional 3-wire connection
Use for direct wire or power supply cord
where local codes do not permit connect-
ing cabinet-ground conductor to neutral
wire.
1. Remove center silver-colored terminal
block screw.
2. Remove neutral ground wire from external
ground conductor screw. Connect neutral
ground wire and the neutral wire (white or
center wire) of power supply cord/cable
under center, silver-colored terminal block
screw. Tighten screw.
B
C
D
E
A. External ground conductor screw
B. Center silver-colored terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire)
E.
³⁄
4
F. Grounding path determined by a qualified electrician
2-12
A
˝ (1.9 cm) UL listed strain relief
C
D
E
F