KitchenAid Pro Line KHEV01RSS Technical Education page 47

Front-loading gas and electric dryers
Hide thumbs Also See for Pro Line KHEV01RSS:
Table of Contents

Advertisement

9.
Remove the four T-20 screws from the
exhaust vent bracket and pull the bracket
off the vent.
2 Screws
Exhaust Vent Bracket
2 Screws
10. Remove the two T-20 screws from the top
blower screws.
11. Remove the four 7/16˝ nuts from the blower
bracket, push the bracket back so it clears
the two chassis studs, and remove it from
under the blower.
2 Screws
Blower
Blower Bracket Nuts
12. Pull the blower down and forward as far
as necessary to access the exhaust high
limit thermostat and temperature sensor.
Blower Down & Forward
13. To remove the exhaust high limit ther-
mostat:
a) Disconnect the two connectors with the
red-silver wires from the terminals.
b) Remove the two nuts from the exhaust
high limit thermostat and remove the
thermostat.
Exhaust High
Limit Thermostat
2 Mounting Nuts
14. To remove the temperature sensor:
a) Unlatch and disconnect the tempera-
ture sensor connectors from the mount-
ing bracket.
b) While holding the round clip with a pair
of pliers, turn the temperature sensor
with your fingers, and push it out of the
clip.
Sensor Connectors
4-7
Red-Silver Wires
Round Clip
Temperature Sensor