Programming The Controls - KitchenAid Pro Line KHEV01RSS Technical Education

Front-loading gas and electric dryers
Hide thumbs Also See for Pro Line KHEV01RSS:
Table of Contents

Advertisement

Diagnostic: Console switches and indicators
Pressing each button or turning the cycle se-
lector to each cycle should cause a beep tone
and control one or more LEDs as shown in Fig-
ure 1. The Estimated Time Remaining display
will indicate a software project i.d. number.
Diagnostic: Moisture Sensor
Locate two metal strips on the inside right wall
or the door well. Bridge these strips with a wet
cloth or a finger. If a continual beep is heard,
the sensor is OK. If not, or if a beep tone is
heard before bridging the moisture strips, go
to TEST #4, step 2.
Diagnostic: Door Switch
Opening the door should cause GAS to be
displayed. Closing the door firmly should cause
the display to indicate the software revision.
Deactivating The Diagnostic Test #1 Mode
Press Pause/Cancel to exit Diagnostic Test
#1 mode.
DIAGNOSTIC TEST #2 –
MACHINE OPERATION
Activating The Diagnostic Test #2 Mode
1.
Be sure the dryer is in Standby Mode
(plugged in and all indicators off).
2.
Press the following button sequence, all
within 3 seconds:
Dryness
Manual Dry
g
Level
Time (–)
3.
After a 2 second pause, Diag will be dis-
played in the Estimated Time Remaining
display for 1 second, if this test mode has
been entered successfully.
4.
Select any cycle and press Start to run
the dryer.
5.
The table shows diagnostic information
that can be obtained while the dryer is
operating and by pressing and holding
the buttons shown in the next column:
Dryness
Manual Dry
g
g
Level
Time (–)
Press button:
Extra Delicate
Casual
Delicate
Heavy Duty
Timed Dry
Rapid Dry
Deactivating The Diagnostic Test #2 Mode
Press Pause/Cancel at any time to exit Diag-
nostic Test #2 mode.
NOTE: Diagnostic mode will automatically
exit after 5 minutes of inactivity since the last
input from the user.

PROGRAMMING THE CONTROLS

If a new control board has been installed, fol-
low the steps below to select the appropriate
fuel (gas or electric).
Menu Mode
This is an operation that is performed at the
factory to calibrate the temperature regulating
sensor/circuit and toggles between a gas and
electric machine (different routines for auto
cycle).
ACTIVATING THE MENU MODE
1.
Be sure the dryer is in Standby mode
(plugged in and all indicators off).
2.
Press the following button sequence, all
within 3 seconds:
Extra Care
Extra Care
g
3.
The Menu mode is active until Pause/
Cancel is pressed. After Pause/Cancel
is pressed, the unit will go into Standby
mode.
Pressing Extra Delicate will set to a
gas model.
Pressing Delicate will set to an electric
model.
4.
Press Start to store setting changes.
DEACTIVATING THE MENU MODE
Pressing Pause/Cancel will exit the Menu mode
and enter the Standby mode.
6-19
Results shown in Estimated
Time Remaining display:
g
Exhaust temperature
g
Tumbler rotation speed
g
Blower rotation speed
g
Number of wet hits
g
Number of running hours
Software revision
g
Dryness Level
Pause/Cancel
g
g

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pro line khgv01rss

Table of Contents