Condenser Fan Motor Replacement - Cornelius VIPER 2 FLAVOR Service Manual

Hide thumbs Also See for VIPER 2 FLAVOR:
Table of Contents

Advertisement

C
F
ONDENSER
AN
© 2008-2012, IMI Cornelius Inc.
Figure 48. Front view of CO
Step
Action
1
Disconnect power from the unit.
2
Remove the access panel (two (2) screws) and the right side panel.
Turn off the CO
3
position.
Relieve pressure in the barrel by opening the relief valve on the faceplate of
4
both barrels.
Disconnect the three (3) supply lines at the rear of the regulators using a small
5
wrench.
6
Remove the two lock nuts from the mounting bracket in back of the regulators.
7
Remove the pressure switch wires from the regulators.
8
Remove the assembly and replace the defective regulator.
9
Reverse the procedure to install the regulator assembly.
10
Check the system for leaks after repressurizing the system.
11
Reset the regulator to the desired setting.
M
R
OTOR
EPLACEMENT
The fan motor is located on the top of the unit, as shown in Figure 49. If the
motor needs replacement, perform the procedure in Table 52. to remove and
reinstall a motor.
CO2 Regulators
Barrel 1
Barrel 2
Regulators w/ Access Panel Removed (2 Barrel Unit)
2
Table 51.
source and then turn the Product valve 90 degrees to the off
2
- 69 -
Viper Service Manual
Publication Number: 621260373SER