Barrel Motor Replacement; Motor Run Capacitor Replacement - Cornelius VIPER 2 FLAVOR Service Manual

Hide thumbs Also See for VIPER 2 FLAVOR:
Table of Contents

Advertisement

Viper Service Manual
B
M
R
ARREL
OTOR
M
R
C
OTOR
UN
APACITOR
Publication Number: 621260373SER
EPLACEMENT
The barrel motor does not require any special alignment when being replaced. It
mounts on four (4) bolts. These bolts are screwed into threaded bosses in the
foam pack barrel assembly, as shown in Figure 43. To replace a barrel motor,
perform the procedure in Table 46..
Barrel Motor
Mounting
Bolts
Figure 43. Side View of Motor Showing Two of the Four Mounting Bolts
Step
Action
1
Perform the procedure in Steps 1 through 8 of Table 43..
2
Disconnect the motor from the circuit by unplugging the connector.
Remove the motor by removing the four (4) bolts holding the motor to the bar-
3
rel assembly.
4
Install the replacement motor and connect the connector.
Replace the motor seal, scraper blade assembly onto the motor shaft in the
5
barrel, as described in Table 43..
6
Reconnect power to the unit.
7
Refill the barrel with product. See "Filling a Barrel" on page 37.
When barrel fill is complete, perform a motor calibration. See "Calibrating a
8
Motor" on page 44.
R
EPLACEMENT
The motor run capacitors, shown in Figure 44, are mounted at the rear of the
unit between the barrel motors. To replace a run capacitor, perform the proce-
dure in Table 47..
Table 46.
- 64 -
Foam
Pack
© 2008-2012, IMI Cornelius Inc.