Hot Gas Solenoid Replacement - Cornelius VIPER 2 FLAVOR Service Manual

Hide thumbs Also See for VIPER 2 FLAVOR:
Table of Contents

Advertisement

H
G
S
OT
AS
OLENOID
© 2008-2012, IMI Cornelius Inc.
Step
Action
9
Reverse the procedure to install the new compressor.
10
Replace the dryer.
Evacuate the system and recharge it according to the Cornelius nameplate on
11
the unit.
12
Replace the side panels and rear cover.
13
Reconnect power to the unit and test the unit.
R
EPLACEMENT
The hot gas valves and solenoids, shown in Figure 50, are located near the cen-
ter of the unit on the right and left sides. Whenever a hot gas valve and solenoid
is replaced, the dryer should be replaced at the same time.
Hot Gas
Solenoid
Figure 50. Hot Gas Solenoid (1 per barrel)
Step
Action
1
Disconnect power from the unit.
2
Remove the side panels.
3
Reclaim refrigerant from the system.
4
Carefully remove the insulation and remove the hot gas valve and solenoid.
5
Replace the hot gas valve and solenoid.
6
Replace the insulation around the valve and solenoid.
7
Replace the filter-dryer.
8
Evacuate the system.
Restore the proper refrigerant charge to the system and verify proper system
9
operation.
- 71 -
Viper Service Manual
Table 53.
Table 54.
Publication Number: 621260373SER