Water Pump Replacement - Cornelius VIPER 2 FLAVOR Service Manual

Hide thumbs Also See for VIPER 2 FLAVOR:
Table of Contents

Advertisement

W
P
R
ATER
UMP
EPLACEMENT
© 2008-2012, IMI Cornelius Inc.
Motor Run
Capacitor
Figure 44. View of Motor Run Capacitors
Step
Action
1
Disconnect power from the unit.
2
Remove the rear cover.
3
Disconnect the spade clips from the defective capacitor.
4
Remove the mounting screw from the base of the capacitor.
5
Replace the capacitor.
6
Reverse the procedure to install the new capacitor.
7
Reconnect power to the unit.
8
Refill the barrel with product. See "Filling a Barrel" on page 37.
When barrel fill is complete, perform a motor calibration. See "Calibrating a
9
Motor" on page 44.
The water pump is located just behind the water filter in the center of the unit. It
is mounted on a bracket facing the rear of the unit. To replace the pump, perform
the procedure in Table 48..
Figure 45. Rear View of Water Pump
- 65 -
Viper Service Manual
Table 47.