INSTALLATION INSTRUCTIONS

S
I
AFETY
NSTRUCTIONS
!
WARNING:
Before starting installation, read and understand all safety label and warnings on the machine. Also review and
understand all safety instructions in the owners, installation and service manuals.
Failure to comply could result in serious injury, death or damage to the equipment.
Q
S
UALIFIED
ERVICE
!
WARNING:
Only trained and certified electrical, plumbing and refrigeration technicians should service this unit.
All wiring and plumbing must conform to national and local codes. Failure to comply
could result in serious injury, death or equipment damage.
S
P
AFETY
RECAUTIONS
This unit has been specifically designed to provide protection against personal injury. To ensure continued
protection observe the following:
!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify
all power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
!
CAUTION:
Always be sure to keep area around the unit clean and free of clutter.
Failure to keep this area clean may result in injury or equipment damage.
Revision Date: August 23, 2017
© 2008-2017, Cornelius Inc.
P
ERSONNEL
www.cornelius.com
- 1 -
Viper 3 Flavor Plumbing Installation Instructions
Publication Number: 629096928INS
Revision: H

Advertisement

loading

Summary of Contents for Cornelius Viper 3

  • Page 1: Installation Instructions

    Viper 3 Flavor Plumbing Installation Instructions INSTALLATION INSTRUCTIONS AFETY NSTRUCTIONS WARNING: Before starting installation, read and understand all safety label and warnings on the machine. Also review and understand all safety instructions in the owners, installation and service manuals. Failure to comply could result in serious injury, death or damage to the equipment.
  • Page 2: Parts List

    NFORMATION AND OUNTING The Viper unit may be mounted on a mobile cart (Cornelius part no. 620043075 for 2-barrel unit, 620053990 for 3-barrel unit and 620046556 for 4-barrel unit) which allows some movement of the unit for service and cleaning.
  • Page 3: Tools Required

    BIB Rack • Regulators • Water Filter Refer to 620043090INS for Cornelius part numbers of Additional Items in list above. Requirements Table 2. Requirements 75±1 psig at the unit 25 psig minimum flowing pressure at the unit with 2.5 gallons per minute flow rate (150gph) per 3 barrels.
  • Page 4 3/8 to 1/4 Inch Fitting Reducer Water Filter 1/4 Inch Tee barb 115 Psig BIB Syrup BIB Pump BIB Pump BIB Syrup BIB Syrup BIB Pump Figure 1. Plumbing diagram Viper 3 Flavor Publication Number: 629096928INS - 4 - © 2008-2017, Cornelius Inc.
  • Page 5 Viper 3 Flavor Plumbing Installation Instructions Viper CO setup Single unit Viper Unit 3/8" Line 75±1 psig 3/8" Line Cylinder 70-75 psig Bag in Box Bag in Box Bag in Box NOTE: Each unit requires a dedicated 3/8" CO line with a regulator located at the unit.
  • Page 6 Viper 3 Flavor Plumbing Installation Instructions Viper CO setup Multiple unit Figure 3. Viper CO setup - multiple unit Publication Number: 629096928INS - 6 - © 2008-2017, Cornelius Inc.