Servicing Motorman Dispensing Valves
© 2008-201, IMI Cornelius Inc.
Step
1.
Open the merchandiser and select OFF for the barrel to be cleaned.
2.
Remove the quick disconnect from the BIB container.
3.
Fill a suitable pail or bucket with soap solution.
Submerge the disconnect in the soap solution and then clean it using a nylon
4.
bristle brush. (Do not use a wire brush). Rinse with clean water and dry.
NOTE: Dispensing valves with caged o-rings should be serviced (lubri-
cated) every six months and o-rings should be replaced once a year.
Refer to Figure 39 and perform the procedure in Table 37. to lubricate or change
the caged o-rings in each dispensing valve on the unit.
Figure 38. Self-Closing Dispensing Valve
Step
1.
Defrost freeze cylinders, shut unit down, disconnect electrical power from Unit.
2.
Perform the procedure in Table 38. to empty the barrels.
- 53 -
Viper Service Manual
Table 36.
Action
Table 37.
Action
Publication Number: 621260373SER