NAME
replacefru - replace a field replaceable unit (FRU)
SYNOPSIS
replacefru
replacefru -h
DESCRIPTION
The replacefru(8) command replaces an FRU. The command allows the user to
select, confirm, and replace the FRU interactively using menus.
The following FRUs can be replaced using the replacefru(8) command.
■
■
■
■
■
■
You must have fieldeng privileges to run this command.
Privileges
Refer to setprivileges(8) for more information.
OPTIONS
The following option is supported.
-h
EXIT STATUS
The following exit values are returned:
0
>0
SEE ALSO
addboard(8), addfru(8), deleteboard(8), deletefru(8), setupfru(8),
showdcl(8), showdomainstatus(8), showfru(8), showhardconf(8), testsb(8),
unlockmaintenance(8)
CPU/Memory Board unit (CMU)
I/O unit (IOU)
FAN unit (FANU)
Power supply unit (PSU)
XSCF unit (XSCFU)
DC-DC converter (DDC_A)
Displays usage statement.
Successful completion.
An error occurred.
replacefru(8)
System Administration
125
Need help?
Do you have a question about the Sun SPARC Enterprise M3000 and is the answer not in the manual?
Questions and answers