Closing The System Unit; Figure 7-2 Attaching The Wrist Strap - Sun Microsystems SPARC classic Service Manual

Table of Contents

Advertisement

To attach a wrist strap:
1. Wrap the grounding strap twice around your wrist.
Make sure the adhesive side is against your skin.
2. Attach the end with the adhesive copper strip to the metal casing of the power
supply in the top of the system unit.
FIGURE 7-2
To detach a wrist strap:
1. Unwrap the grounding strap from your wrist.
2. Detach the end with the adhesive copper strip from the metal casing of the power
supply in the top of the system unit.
7.4

Closing the System Unit

To close the system unit:
1. Preparation.
a. Check that there are no loose tools or screws in the unit.
b. Check that all SBus cards and SIMMs are seated properly.
c. Check that all internal cable connections are tight.
7-4
SPARCclassic/SPARCclassic X/SPARCstation LX Service Manual • November 1993
Wrap the wrist strap twice around
your wrist (adhesive against your skin)
Attaching the Wrist Strap
Attach end to metal
case of power supply
.
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc station lx

Table of Contents