NOTE
Product Reference Guide
Figure 2-28. Using the Bubble Level
Bubble Level
6. Re-install the Platter and verify that it is flush or just below flush
with the countertop. This is necessary to provide smooth scanning
from either direction. Make adjustments as needed to align the plat-
ter with the counter by moving support rails up or down, or con-
sider installing screws in positions that will allow their use in
adjusting the unit's position. Ensure that leveling is maintained if
adjustments are made.
Failure to install a scanner/scale in a stable and level position
will inhibit weighing, calibration and zeroing operations. The
platter MUST make unobstructed contact with all of its supports
for proper weighing operation.
7. Once installation is complete, proceed with the
fication
procedures that follow.