Datalogic Magellan 8300 Product Reference Manual page 528

In-counter scanner/scales
Hide thumbs Also See for Magellan 8300:
Table of Contents

Advertisement

G-6
EAN-13
Check digit must be included in label data and is assumed to be cor-
rect
Prefix must be an ASCII character 'F'- total length including prefix
must be 14
Example: 'F1101234567891'
EAN-13 with 2-Digit Supplemental
Check digit must be included in label data and is assumed to be cor-
rect
Supplemental data is appended to base label
Prefix must be an ASCII character 'F'- total length including prefix
must be 16
Example: 'F110123456789112'
EAN-13 with 5-Digit Supplemental
Check digit must be included in label data and is assumed to be cor-
rect.
Prefix must be an ASCII character 'F'- total length including prefix
must be 19.
Example: 'F110123456789112345'.
EAN-13 with Code 128 Supplemental
Check digit must be included in label data and is assumed to be cor-
rect
Supplemental data is appended to base label
Prefix must be an ASCII character 'F'- total length including prefix
must be greater or equal to 20 (code 128 Supplemental codes are
variable length having a minimum of 2 data characters)
Characters immediately following base label must be of the form
'8100', '8101' or '8102'
Example: 'F11012345678918100000951'
TM
Magellan
8300/8400

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magellan 8400

Table of Contents