RS-232 ACK NAK Timeout Value
6-124
This item specifies the time the scanner will wait for an ACK character
from the host following a label transmission.
0 = Infinite timeout
1 - 75 = Timeout in 200-millisecond increments
To set the ACK NAK Timeout Value:
1. Scan the SWITCH bar code.
2. Scan the bar code below,
VALUE
. You'll need to cover any unused bar codes on this and the
facing page to ensure that the scanner reads only the bar code you
intend to scan.
3. Scan the appropriate digits from the keypad in
resent the desired timeout. A setting of 0 specifies an infinite time-
out. The remaining selectable range is 1-75, which is the timeout in
200-millisecond increments. Pad all single digit numbers with lead-
ing zeroes to yield a three-digit entry (000-075).
Examples:
000 = Infinite timeout
001 = 200ms
005 = 1,000ms (1 second)
040 = 8,000ms (8 seconds)
075 = 15,000ms (15 seconds)
4. The scanner will automatically exit Programming Mode when the
appropriate amount of digits have been scanned.