Motion Test

Automatic Zero Tracking Test

NOTE
Product Reference Guide
This test verifies that the scale will not 'zero' when the weighing surface of
the scanner/scale is in motion.
1. Verify that the Yellow LED
0.00 pounds or 0.000 kilograms.
2. Press lightly on the weigh platter of the scanner/scale with one hand
and at the same time press and release the Zero Push Button on the
operator's panel. The Yellow LED should turn Off and the Remote
Display should not display 0.00 pounds or 0.000 kilograms.
3. Remove your hand from the weighing platform and verify that the
Yellow LED is On and the Remote Display reads 0.00 pounds or
0.000 kilograms.
This test verifies that the scanner/scale automatic zero tracking mecha-
nism is operating correctly.
1. Place 0.006 pounds (3 grams for metric) on the center of the weigh-
ing platform. The entire weight must be placed on the weighing
platform at once for this test to be valid. The Yellow LED should go
Off and the Remote Display should read 0.01 pounds (0.005 kilo-
grams).
The scanner/scale has an adaptive zero capture mechanism
that re-zeros the scale over time if there is a slow change in the
zero level; thus if all the weight is not placed on the weighing
surface at one time, the Yellow LED will remain On and the
Remote Display will read 0.00 pounds (0.000 kilograms). When
the weight is removed, the Yellow LED will turn off and the dis-
play will show a minus sign
ton to re-zero the scale.
1. Yellow LED indications can be configured via feature programming and may not
be enabled for certain functions.
1
is on and the Remote Display reads
. Press the Zero Push But-
.
lb