5. Start the twin generators (engines) and confirm that both generators started. The
starting procedure is same as the normal starting procedure. (See"STARTING THE
ENGINE"of the operation manual.)
Note: Confirm the bellows before starting the both generators.
(1). Make sure two PARALLEL I/O terminals on either control panel have been
connected reliably with special communication cable.
(2). The parallel cable has been connected to the PARALLEL OUTPUT terminals on
each generator control panels.
If either of above mentioned two connections hasn't been done properly, either
generator won't output power while starting generators, even generators will be
damaged.
6. Securely plug the electrical appliance plug
on the electrical appliance power supply. Fig. 5
Fig. 5
Note:
The required output of the electrical appliance cannot exceed the rated output of
parallel generators.
Shut off the generators:
1. Turn off the power of electrical appliance, pull out the receptacle plug.
2. Turn off the two generators.
3. First disconnect the cable on the PARALLEL OUTPUT terminals of the two
generators. And then remove the PARALLEL I/O parallel connection cable.
into parallel cable receptacle
, switch

6. GENERATOR USE

Be sure to ground the generator when the connected equipment is grounded.
WARNING
To prevent electrical shock from faulty appliances, the generator should be
grounded. Connect a length of heavy wire between the generator's ground
teminal and an external ground source.
Connections for standby power to a building's electrical system must be made
by a qualified electrician and must comply with all applicable laws and electri-
cal codes. Improper connections can allow electrical current from the generator
to backfeed into the utility lines. Such backfeed may electrocute utility company
workers or others who contact the lines during a power outage, and when utility
power is restored, the generator may explode, burn, or cause fires in the
building's electrical system.
GROUND MARK
GROUND TERMINAL