NOTE: The Low Oil Alarm System will automatically stop the engine before the oil level
falls below the safe limit. However, to avoid the inconvenience of an unexpected
shutdown, it is still advisable to visually inspect the oil level regularly.
OIL FILLER CAP
OIL FILLER HOLE
2. Check the fuel level.
Use automotive gasoline (Unleaded or lowleaded is preferred to minimize combustion
chamber deposits).
If the fuel level is low, refuel the fuel tank until the level increased to the specified mark.
Never use an oil/gasoline mixture or dirty gasoline.
Avoid getting dirt, dust or water in the fuel tank.
After refueling, tighten the fuel filler cap seurely.
WARNING
Gasoline is extremely flammable and is explosive under certain conditions.
Refuel in a well-ventilated area with the engine stopped. Do not smoke or
allow flames or sparks in the area where the engine is refueled or where
gasoline is stored.
Do not overfill the fuel tank (there should be no fuel above the upper limit mark).
After refueling, make sure the tank cap is closed properly and securely.
Be careful not to spill fuel when refueling. Spilled fuel or fuel vapor may ignite,
If any fuel is spilled, make sure the area is dry before starting the engine.
Avoid repeated or prolonged contact with skin or breathing of vapor. KEEP
OUT OF REACH OF CHILDREN.
UPPER LEVEL
4.SPARK ARRESTER MAINTENANCE(Equipped type only)
WARNING
If the generator has been running, the muffler will be
very hot. Allow it to cool before proceeding.
CAUTION
The spark arrester must be serviced every 100 hours
to maintain its efficiency.
1.Remove the four 5 mm screws, and remove the muffler protector.
2.Remove the there 6 mm bolts, and remove the muffler, the spark arrester and the
muffler gasket