5. Visually inspect the spark plug. Discard it if the insulator is cracked or chipped.
Clean the spark plug with a wire brush if it is to be reused.
6. Measure the plug gap with a feeler gauge.
The gap should be 0.5-0.75mm(0.02-0.03in). Correct as necessary by carefully
bending the side electrode.
CAUTION
The spark plug must be securely tightened. An improperly tightened plug
can become very hot and possibly damage the generator.
Never use a spark plug with an improper heat range.
7. Install the spark plug carefully, by hand, to avoid cross-threading.
8. After a new spark plug has been seated by hand, it should be tightened 1/2 turn
with a wrench to compress its washer.
If a used plug is being reinstalled, it should only required 1/8 to 1/4 turn after being
seated.
9. Reinstall the spark plug inspection cover and tighten the cover screw.
10. Close and latch the left side maintenance cover.
Plug gap
0.5-0.75
Fig. 16
-18-

5.GENERATOR USE

WARNING
To prevent electrical shock from faulty appliances, the generator should be
grounded. Connect a length of heavy wire between the generator's ground
terminal and an external ground source.
CAUTION
Limit operation requiring maximum power to 30 minutes. For continuous
operation do not exceed the rated power. In either case, the total wattage of
all appliances connected must be considered.
Do not exceed the current limit specified for any one receptacle.
Do not connect the generator to a household circuit. This could cause the
damage to the generator or to electrical appliances in the house.
Do not modify or use the generator for other purposes than it si intended for
Also observe the following when using the generator.
Do not connect an extension to the exhaust pipe.
When an extension cable is required, be sure to use tough rubber sheathed
flexible cable.
Limit length of extension cables; 60 m for cables if 2.5mm
2
cables of 4mm .
Keep the generator away from other electric cables or wires such as
commercial power supply lines.
CAUTION
You may use DC receptacle when using AC supply.
If you want to use AC and DC receptacle simultaneously, the total output
should not be over the sum output of AC and DC.
Electrical equipment containing the wiring and plug should not have defect.
2
and 100m for
-11-