6.GENERATOR USE

WARNING
To prevent electrical shock from faulty appliances, the generator should be
grounded. Connect a length of heavy wire between the generator's ground
terminal and an external ground source.
Connections for standby power to a building's electrical system must be made by
a qualified electrician and must comply with all applicable laws and electrical
codes. improper connections can allow electrical current from the generator to
backfeed into the utility lines. Such backfeed may electrocute utility company
workers or others who contact the lines during a power outage, and when utility
power is restored, the generator may explode, burn, or cause fires in the building's
electrical system.
CAUTION
Maximum power is available in the first 30 minutes. For continuousoperation,
do not exceed the rated power. In either case, the total wattage of all
appliances con-nected must be considered.
Do not exceed the current limit specified for any one receptacle.
Do not connect the generator to a household circuit. This could cause the
damage to the generator or to electrical appliances in the house.
Do not modify or use the generator for other purposes than it is intended for.
Also observe the following when using the generator.
Do not connect an extension to the exhaust pipe.
When an extension cable is required, be sure to use a tough rubber
sheathed flexible cable.
(IEC245DV equivalent)
Limit length of extension cables; less than 60 m for cables if 2.5mm
and less than 100m for cabes of 4.0 mm
Keep the generator away from other electric cables or wires such as
commercial power supply lines.
Electrical equipment(including lines and plug connections) should not be
defective.
,
2
2
.
8.MAINTENANCE
The purpose of the maintenance and adjustment schedule is to keep the generator
in the best operating condition.
WARNING
Shut off the engine before performing any maintenance.
If the engine must be run, make sure the area is well ventilated. The exhaust
contains poisonous carbon monoxide gas.
CAUTION
Use genuine parts or their equivalent. The use of replacement parts which are
not of equivalent quality may damage the generator.
Maintenance Schedule
REGULAR SERVICE PE-
RIOD(1) Perform at every
EACH
indicated month or operating
hour interval, whichever occurs
USE
first.
ITEM
Check
Engine oil
Change
Check
Air cleaner
Clean
Spark plug
Clean-adjust
Spark arrester
Clean
Fuel sediment cup
Check-adjust
Valve clearance
Fuel tank and strainer
Clean
Every 2 years (Replace if necessary)(3)
Fuel line
Check
(1) Log hours of operation to determine proper maintenance.
NOTE:
(2) Service more frequently when used in dusty areas.
(3) These items should be serviced by an authorized dealer, unless the owner has the
proper tools and is mechanically proficient. See the Shop Manual.
FIRST
EVERY 3
EVERY 6
EVERY
MONTH
MONTHS
MONTHS
YEAR
OR
OR
OR
OR
100 HRS
300 HRS
10HRS
50HRS
(2)
(3)
(3)