8.
PERIODIC CHECK AND SERVICE
Periodic check and service are very important for keeping the engine in good
condition and durable. The chart below indicates what checks to make and when
to make them.
WARNING
Shut off the engine before performing any service. If the engine must be run, make
sure the area is well ventilated. The exhaust contains poisonous carbon monoxide
gas.
After the generating set has been used, clean it immediately with a cloth to prevent
8.1Maintainace table:
Interals
Every
month
Item
Check and refill oil
Drain out fuel oil
Check and refill engine oil
Check for oil leakage
Check and tighten fastening parts
Replace engine oil
Clean engine oil filter
Replace air cleaner element
shorter maintainance period for dusty area
Clear fuse element
Check fuel injection pump
Check nozzle
Check fuel pipe
Adjust clearance of intake/exhaust valves
Grind intake/exhaust valves
Replace piston ring
Check battery electrolyte
Check carbon brush and slip ring
Check insulation resistance
The generating set has been stored more than 10days
Note:
indicates that special tools are required, please contact with KIPOR agent.
Sixth month
First month
Third month
Every year
or
or
or
or
500 Hrs
20 Hrs
100 Hrs
1000 Hrs
Tighten the
cylinder head bolts
(After se-
(First time)
cond time)
(Replace if
necessary)
Replace
Every month
3.5How to open the cabinet door and
covers of the silent generator set.
1. Turn the lever clockwise and open the
cabinet door for daily inspection.
2. Loosen the bolt of the air cleaner check
port cover to check the air cleaner.
3. Screw off the wing nut to open the cover
of nozzle, then check the nozzle.
3.6 Break-in period operation
The first 20hrs are the break-in period of the engine, the operator must obey to
following items:
Warm up the engine 5 minutes after the initial starting. Run the engine at low
speed and zero load before the engine becomes warm.
Avoid applying any heavy loads during the break-in period. KIPOR
recommends to run the engine at 3000r/min with 50% load in break-in period.
Replace the oil on time.
Replace the oil while the engine is warm after 20-hours-running, the old oil will
be drained out completely.
Approx.one month or 20hours
4.

START THE GENERATOR SET

WARNING
DO not hook up tools or other apparatus to the generator set before
starting.
Door lock
Every 3 months or 100 hours

Advertisement