High altitude operation

At high altitude, the standard carburetor air-fuel mixture will be excessively rich.
Performance will decrease, and fuel consumption will increase.
High altitude performance can be improved by installing a smaller diameter main fuel jet
in the carburetor and readjusting the pilot screws. If you always operate the generator at
altitudes higher than 1,500 m (5,000 feet) above sea level, have your authorized dealer
perform these carburetor modifications.
Even with suitable carburetor jetting, engine horsepower will decrease approximately
3.5% for each 300m (1,000 feet) increase in altitude. The affect of altitude on the
horsepower will be greater than this if no carburetor modification is made.
CAUTION
Operation of the generator at an altitude lower than the carburetor is jetted for
may result in reduced performance, overheating, and serious engine damage
caused by an excessively lean air/fuel mixture.
WARNING:
The special parallel cable for our IG2000p is only applicable to the parallel operation
of two IG2000p generators. It can not be used for paralleling three or above three
generators.
Be sure only use parallel output cable for parallel running. Other cables are
forbidden.
While connecting the generator and electrical appliance with the parallel output
cable, do carefully and safely insert the plug into the receptacle.
While operating parallel, only output through the receptacle on the parallel cable
wire, don't use the receptacle on the control panel of the generator.
Make sure insert the plugs on the parallel cable wire to the related proper
receptacles.
Make sure the output is directly from the receptacles on the parallel output cable
while parallel running, instead of the receptacles on the generator control panels.
Don't disconnect the PARALLEL I/O special connection cable and parallel output
cable during the parallel running, connect the PARALLEL I/O special connection
cable before start the engine, and then connect the parallel output cable. You can
disconnect the PARALLEL I/O special connection cable and parallel output cable
only after stopping the generator.
If the parallel output cable is still connected, cut off the current output after either
generator was shut off.
Don't use the parallel output cable and parallel connection cable while operating two
generator separately.
Don't connect the parallel cable wire while the two generator running singly.
Read IG2000p operation manual before using the generator.