3.9 No DC output

Is the engine speed normal?
Check the DC output*
Check the DC output
Measure the resistance between the
blue terminals of the rectifier.
Resistance: 0.12~0.15Ω
Rotor losses magnetism and replace the
rotor.
*later models had a fuse in the receptacle. Check the fuse before replacing the receptacle.
3.10 No Parallel Output (prior to 2011 model year)
■ Make sure that the parallel output cables are inserted into the parallel cable connectors on the
control panel..
.
■ Use only KIPOR parallel output cables.
■ Use only the KIPOR parallel output box.
■ Don't use any control panel receptacles when running in parallel..
■ Don't disconnect the parallel cables while either generator is operating.
Check whether the two generators could
work well separately.
Is one of the over load indicating light
on?
Check the paralleled I/O communication
wire
Check the paralleled I/O communication
receptacle
Replace the inverter unit
Normal
Normal
Normal
Normal
Normal
On
Normal
Normal
23
Perform the throttle control system
Abnormal
test.
Abnormal
Replace the DC receptacle
Abnormal
Replace the rectifier.
Abnormal
Check the wire harness, or replace
the stator.
Perform
Abnormal
troubleshooting
Off
1. Check the parallel output cable
2. Check the parallel output terminal
Abnormal
Replace
communication wire
Replace
Abnormal
communication receptacle
single
generator
the
parallel
I/O
the
parallel
I/O