5) If adjustment is necessary, proceed as follows.
a. Loosen the adjusting screw lock nut and adjust the valve clearance by turning the adjusting
screw in or out.
b. Secure the adjusting screw with a socket wrench and tighten the lock nut to the specified
torque.
c. After tightening the lock nut, check the valve clearance again.
塞尺
Feeler gauge
6) Clean the liquid gasket of the cylinder block and cylinder head cover. Apply the liquid gasket
(Three Bond 1207B or equivalent) to the cylinder block installation surface as shown.
Liquid gasket 1.5-2.0 in diameter
直径1.5-2mm密封胶
7) Install the removed parts in the reverse order of removal.