9.2 No AC Power-Appliance does not operate
Is the output indicator light ON?
YES
Check the electrical appliance or
equipment for any defects.
9.3 No electricity at the DC receptacle:
Is DC circuit fuse burned out?
NO
Is the overload
indicator light ON?
YES
YES
NO
NO
Take the generator to an
authorized dealer.
NO
Take the generator to an
authorized KIPOR dealer.
■ Replace the electrical
appliance or equipment
■ Take the electrical appli-
ance or equipment to an
electrical shop for repair
YES
Replace the fuse
Take the generator to an
authorized KIPOR dealer.
-27-