3. Drain out the oil inside engine and check the conductivity, conducivity is normal.

4.3 Air cleaner

Inspection/Cleaning:
1) Loosen the cover screw and remove the maintenance cover.
2) Disengage the locking tab by pushing it, and remove the air cleaner cover.
3) Remove the element from the air cleaner case.
4) Clean the element in warm soapy water, rinse and allow to dry thoroughly, or clean with a high
flash point solvent and allow to dry.
Dip the element in clean engine oil and squeeze out the excess oil.
Excess oil will restrict air flow through the foam element and may smoke at engine start.
5) Install the air cleaner element in the air cleaner case.
6) Clean the air cleaner sealr and the air cleaner case if necessary. Be sure that the air cleaner
cover seals are set securely..
7) Install the maintenance cover securely.