Trigger Adjustment - Kipor IG2000 Shop Manual

Epa/carb/cetl certified models
Hide thumbs Also See for IG2000:
Table of Contents

Advertisement

(4) Main winding
Measure the resistance among the main winding terminals.
Black-Black-Black
Resistance
1.35~1.75
(5) Trigger
Attach the two testers in the trigger, and measure its resistance.
Trigger resistance
80-130Ω
10.3 Adjustment
Adjust the clearance between trigger and the projection part of rotor.
Trigger clearance
0.50-0.75mm
Insert a feeler gauge between the trigger and the projection part of the rotor; loosen the trigger
fixed plate bolt to adjust the clearance slightly. Never move the plastic part of trigger.