Keyboard Interface
Wedge Quiet Interval
Specifies the amount of time the reader looks for keyboard activity before it breaks the keyboard
connection in order to transmit data to host. The range is from 0 to 990ms in 10ms increments.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with lead-
3. Go to
4. Scan the barcode: SELECT WEDGE QUIET INTERVAL SETTING.
5. Scan the appropriate two digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit.
This completes the procedure to set the Wedge Quiet Interval. See
of how to set this feature.
Table 35. Wedge Quiet Interval Setting Examples
STEP
ACTION
1
Desired Setting
Divide by 10 (and pad with
2
leading zeroes)
3
4
Scan Two Characters From
5
Appendix D, Keypad
6
Product Reference Guide
This feature applies ONLY to the Keyboard Wedge interface.
ing zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
page 62
and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter
Prog. Mode.
the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
10ms
01
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT WEDGE QUIET INTERVAL SETTING
'0' and '1'
Scan ENTER/EXIT PROGRAMMING MODE
Appendix D,
Table 35
EXAMPLES
150ms
600ms
15
60
'1' and '5'
'6' and '0'
Keyboard Interface
Keypad, that represent
for some examples
850ms
85
'8' and '5'
299