6. Mechanical adjustment
6.
Mechanical adjustment
6.1
Paper Feed Unit CD Registration Adjustment
NOTE
• This adjustment is to be made when the PH Unit has been replaced.
1. Load the Paper Feed Unit with A4 crosswise paper.
2. Enter Function of the Service mode.
3. Select "Print Test Pattern" and then "Test Pattern1." Then, press the Start key.
✽ This will produce a test pattern.
A
14
4. Check width A on the test pattern.
If width A falls outside the specified
range, perform the following steps to
make an adjustment.
Specifications
20 ± 2.0 mm
4686D504AA
5. Slide out the Paper Feed Unit and
loosen one screw.
4686U025AB
6. If width A is greater than the speci-
fied range, move the Edge Guide in
the direction of the arrow.
4686U088AB
Field Service Ver. 1.0 Apr. 2005