Konica Minolta Bizhub 162 Service Manual page 339

All in one printer
Hide thumbs Also See for Bizhub 162:
Table of Contents

Advertisement

11. Soft Switch Set
11.7.11
SOFT SWITCH: #11
Bit
Designation
No.
8
Reserved
Detect dial tone after
7
pre-fix number
Pulse dial allowed to
6
select
5
Reserved
4
Reserved
3
Reserved
2
Reserved
DTMF high frequency
1
dB value
• Bit 6
: If this bit is set to 1, not allowed user to select Pulse dial, and this function open
for serviceman to change.
• Bit 7
: Bit set to 1, LCD will show the command between each party.
11.7.12
SOFT SWITCH: #12
Bit
Designation
No.
8
ECM mode capability
7
V.34 fall back level for
V.34 TX.
6
5
Send CTC after 4th PPR
4
Reserved
Send EOR after lowest
3
speed
2
TCF transmission timing
after DCS
1
• Bit 1-2 : Delay time from FSK mode to PSK mode, this is used for G3 mode only, V.34
does not need this setting.
• Bit 6-7 : If level reads "1", machine. Will go down to next lower speed for next data
phase.
122
Function
Reserved
0 : No
1 : Yes
0 : Yes
1 : Not allowed
Reserved
Reserved
Reserved
Reserved
0 : Base on SW19 (1-4)
1 : High 1dB
Function
1 : Yes
0 : No - also disable V.34 modem capability
Counter
1
Bit 7
0
Bit 6
0
0 : Send CTC (Continue To Correct)
1 : Send EOR (End Of Transmission)
Reserved
0 : Send DCN (Redial)
1 : Send EOR_xxx (Germany PTT)
Description
70 ms
Bit 2
0
Bit 1
0
Field Service Ver. 1.0 Apr. 2005
2
3
4
0
1
1
1
0
1
80 ms
90 ms
100 ms
0
1
1
1
0
1
Initial
Setting
Bit
HEX
0
0
0
0
0
0
0
0
0
0
Initial
Setting
Bit
HEX
1
0
8
0
0
0
0
0
0
0