Field Service Ver. 1.0 Apr. 2005
11.7.21
SOFT SWITCH: #21
Bit
Designation
No.
8
NSS signal before DCS
7
CNG duration after dial-
ing (T1)
6
5
T4 timer
4
Reserved
3
DIS signal length
2
Increase default T1 tim-
ing during calling
1
• Bit 1-2 : T1 indicates the calling time after dialing, can adjust the T1 time longer by
changing the default value. The default T1 timer depends on each country reg-
ulation.
• Bit 3
: Some old machines can not accept DIS command over 4 bytes, and every time
will become fail. In this case you can set this bit to 1. If this bit is set to 1, JBIG
and V8 capability will be disabled automatically.
• Bit 6-7 : A fax to be received is canceled and the machine becomes unable to receive it
if the setting of "No. of RINGS" is made longer than the setting of "CNG duration
after dialing." Be sure to make the "No. of RINGS" setting to a value shorter
than the "CNG duration after dialing" setting.
• Bit 8
: Sender machine's name will show on the other party's LCD or print on the
report if remote side is the same model.
Function
0 : Not to send NSS signal if remote side is same
model
1 : Send NSS signal if remote side is same model
Duration
40 sec
Bit 7
0
Bit 6
0
0 : 3.0 sec – Normal case
1 : 4.5 sec
Reserved
0 : Normal length (bit 1 to 64)
1 : 4 bytes DIS command – bit 1 to 32 only
Descrip-
T1 sec T1+ 30 sec T1+ 40 sec T1+ 60 sec
tion
Bit 2
0
0
Bit 1
0
1
11. Soft Switch Set
60 sec
70 sec 120 sec
0
1
1
1
0
1
1
1
0
1
Initial
Setting
Bit
HEX
1
1
C
0
0
0
0
0
0
0