Field Service Ver. 1.0 Apr. 2005
10.3.4

DISPLAY

• DISPLAY displays various types of information.
A. TONER DENSITY LEVEL
Purpose/Use
To display the current output value of ATDC sensor.
Refer to the following table for actual T/C values.
Used to check the T/C ratio when the image density is defective.
Display
B. PROCESS CONTROL
Purpose/Use
To display the Vg and Vb values.
Display
-5
0
+5
C. MAIN F/W VER. (PWB-C/C)
Purpose/Use
To display the main firmware version information.
D. ENGINE F/W VER. (PWB-A)
Purpose/Use
To display the engine firmware version information.
E. PCL F/W VER.
Purpose/Use
To display the PCL firmware version information.
Only when the optional Printer Controller (Pi2001e) is mounted
F. NIC F/W VER.
Purpose/Use
To display the NIC firmware version information.
Only when the optional Network Interface Card (NC-502) is mounted
80
100
130
135
140
145
Vb (V)
-300
-400
-500
10. Service Mode
T/C
8.0%~8.4%
10.0%~10.4%
13.0%~13.4%
13.5%~13.9%
14.0%~14.4%
14.5%~14.9%
Vg (V)
-450
-550
-650