11. Soft Switch Set
11.7.18
SOFT SWITCH: #18
Bit
Designation
No.
8
Reserved
7
Reserved
6
G3 mode training qual-
ity level
5
4
3
2
Redefine re-dial
attempts counter
1
• Bit 1-4 : The redial attempt times will follow bit 1- 4, if these bits are not all setting "0".
Otherwise the redial attempt times will follow bit 1 to 4 on SW08.
• Bit 5-6 : Level 4 training check phases is most severe than level 3, 2, 1. Level 4 can keep
lowest RX speed communication than level 3, 2, 1 when poor line condition.
126
Function
Reserved
Reserved
Definition
Level1
Bit 6
0
Bit 5
0
Counter
0
1
2
Bit 4
0
0
0
Bit 3
0
0
0
Bit 2
0
0
1
Bit 1
0
1
0
Counter
Reserved
Bit 4
1
1
1
Bit 3
0
1
1
Bit 2
1
0
0
Bit 1
1
0
1
Field Service Ver. 1.0 Apr. 2005
Level2
Level3
Level4
0
1
1
1
0
1
3
4
5
6
7
8
9 10
0
0
0
0
0
1
1
1
0
1
1
1
1
0
0
0
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
1
1
1
1
1
0
1
Initial
Setting
Bit
HEX
0
0
0
0
0
0
0
0
0
0