Length
Definition:
Specifies the length of the decoded symbol allowed to occupy this location in
multisymbol output.
Note: To filter or order a symbol, the symbol must meet all requirements of
the selected filter index.
Serial Cmd: <K744,filter number,symbology,length,wildcard,placeholder,data,
unused,database index>
Default:
0
Options:
0 to 64
Wildcard
Definition:
This is the character to be used in the data output field when performing a
data filter comparison. The wildcard character represents the end of matching,
and allows for variable lengths of symbol output.
Serial Cmd: <K744,filter number,symbology,length,wildcard,placeholder,data,
unused,database index>
*
Default:
"
" =
Options:
Any ASCII input in the form of a pair of hex characters.
Example:
2A =
00 = disabled
Placeholder
Definition:
The placeholder character requires a character to be present, but does not
compare the data value.
Serial Cmd: <K744,filter number,symbology,length,wildcard,placeholder,data,
unused,database index>
Default:
"
?
" =
Options:
Any ASCII input in the form of a pair of hex characters.
Example:
3F = ?
00 = disabled
MS-4Xi Imager User's Manual
2A
(hex)
*
3F
(hex)
Output Format