Request Master Symbol Data

Definition:
Returns master symbol data for any enabled master symbols from 1 to 10.
For example, to request master symbol # 5, enter <K231?,5>. The imager
transmits master symbol # 5 data in brackets in the following format: <5/>.
If no master symbol data is available, the output will be: <5/>.
Serial Cmd:
<K231?,master symbol
Caution: Be sure to add the
Note: This command returns the number of master symbols if no number is
included.
ESP:
1. Click the Utilities button and the Master Database tab.
2. Click the Receive Reader's Database button.

Request All Master Symbol Data

Definition:
This command will return master symbol data for all symbols enabled (up to 10).
Serial Cmd:
<K231?>
MS-4Xi Imager User's Manual
number>
?
or you will delete the master symbol.
Utilities