No Read Message

Usage:
Used in applications where the host needs serial verification that a symbol
has not been read and especially useful in new print verification.
Definition:
When enabled, and if no symbol has been decoded before timeout or the
end of the read cycle, the No Read message will be transmitted to the host.
No Read Message Mode
Serial Cmd:
<K714,No Read message
Default:
Enabled
Options:
0 = Disabled
Disabled
Only symbol data is output after a read cycle.
Enabled
When the imager is in a triggered mode, a No Read message will be appended for each
failed read attempt.

No Read Message

Definition:
Any combination of ASCII characters can be defined as the No Read
message.
Serial Cmd:
<K714,No Read message
Default:
NOREAD
Options:
A string of up to 64 characters.
Note: No Read Message will only be transmitted if Symbol Data Output is set to Match,
Mismatch, or Good Read.
No Read Message can be set to any ASCII character.
Important: The ASCII characters <, >, and
For <:
<K714h,,3C>
For >:
<K714h,,3E>
,
For
:
<K714h,,2C>
MS-4Xi Imager User's Manual
status,No Read message>
1 = Enabled
status,No Read
,
can only be entered as hex pairs:
I/O Parameters
message>
7-7