Service Message
Service Message
When Service Message is enabled, a message of up to 10 ASCII characters is sent
whenever the system detects that the service timer's limit has been reached. The service
timer is reset at power-on, meaning that the service timer's limit is the amount of time
since last reset. Service timer increments can be set in seconds or minutes.
Serial Cmd:
<K409,status,service message,threshold,resolution>
Default:
0
Options:
0 = Disabled
Service Message
Serial Cmd:
<K409,status,service
Default:
SERVICE
Options:
An ASCII string between 1 and 10 characters.
Important: The ASCII characters <, >, and
For <:
<K409h,,3C>
For >:
<K409h,,3E>
,
For
:
<K409h,,2C>
Threshold
Serial Cmd:
<K409,status,service message,threshold,resolution>
Default:
300
Options:
1 to 65535
Resolution
Serial Cmd:
<K409,status,service message,threshold,resolution>
Default:
Seconds
Options:
0 = Seconds
7-34
message,threshold,resolution>
(5 minutes)
1 = Enabled
,
can only be entered as hex pairs:
1 = Minutes