Splice one of the ignition sensing wires to the purple switch power
wire on the CM20018 harness (see figure 6-5) using 16AWG (1.3 mm
)
2
wire to make any necessary extensions. Use crimped Molex Perma-
Seal (or equivalent) butt splice connectors, or shrink-sealed solder
connections. Locate all splices in a dry location and secure them
properly against mechanical damage.
Connect the second purple ignition sensing wire to the gray troll
switch power wire on the Suzuki switch panel harness (see figure 6-5).
The troll switch wire is supplied with a crimped female bullet connector,
sealed with a black plastic plug. A mating bullet connector is included
in the bag with the CM20018 harness. Crimp it to your ignition
extension wire, then simply push the male connector bullet into the
female receptacle to complete the connection (see figure 6-7). If
required, additional bullet connectors can be ordered through a
Suzuki distributor, using Suzuki part number 36990-87D00.
If the vessel is fitted with a Suzuki troll mode switch the troll switch
wire will already be connected. In this case, the troll switch harness
has an alternate point to connect the ignition. Look for the female
bullet connector with two gray wires crimped into it.
CRIMP MALE BULLET
PER MANUFACTURER'S
INSTRUCTIONS
FEMALE CONNECTOR
Figure 6-7. Male and female bullet connector.

6.3 Suzuki SPC System Calibration

The Suzuki SPC system must be configured and calibrated in order
to work with the Optimus joystick system. To calibrate the system you
will need the Suzuki Diagnostic System (SDS) tool and the Suzuki
diagnostic interface adapter (Suzuki part number 09933-19830).
Connect the interface adapter and start the software according to
the instructions provided by Suzuki.
When the software starts up you'll see the home screen shown in
Figure 6-8. If you are updating an existing installation, click bcm
Initialization to clear the existing calibration from memory, then cycle
the power (leave off for ten seconds). Otherwise, continue with the
following steps.
6-6
© 2014 SeaStar Solutions
Optimus 360 Installation Supplement, Rev. B